Please Note: You are viewing the unstyled version of ATC, Inc. Either your browser does not support CSS (Cascading Style Sheets) or it is disabled. As a result, much of this website will not look the way it was intended, although all of its contents will be accessible to you. For more information, visit our Browser Support page.


Skip to Primary Site Navigation, Secondary Site Navigation, Content, Company Address


Model ME2

Model ME2

Instrument Applications:

  • Leak testing under vacuum
    • Slip and viscous flow regime (2 psia to barometric pressure)
    • Leak Tightness from 1X10-5 sccs at 2 psia (1 µm defect size); or
    • Hard vacuum - Molecular Flow (less than 0.1 psia)
    • Leak Tightness from 5X10-7 sccs at 0.02 psia (0.1 µm defect size)
  • Mass Extraction tests
  • Medium size parts, higher throughput
  • Cleanroom or industrial applications
Leak Test Simulator button

Leak Test Simulator: Use our Leak Test Simulator to optimize your application and define your micro-flow sensor/instrument.

Available Options: Please see ATC's options chart.

Features:

Applicable Micro-Flow Sensors (IGLS):

  • Vacuum Sensor: Model IL2-M, calibrated from 2 psia (slip and viscous flow regimes)
  • Hard Vacuum Sensor:Model IMFS, calibrated from 0.01 to 0.2 psia (Molecular and transitional flow regimes)

Specifications

Dimensions & Access:

  • 17”W, 24”H, 19”D (Does not include connectors & fittings)
  • Optional Cart Size: 28”W, 47”, 20”D
    • Expansion tank, vacuum generation and control package are externally mounted on optional cart

Gases:

ME2 Specifications

Click to Enlarge

  1. Digital Inputs: 5 VDC, NPN Opto-Isolated for start, stop, type, pressure
    switch, verify. Digital Outputs: 30 VDC-20 mA, NPN, opto-isolated for
    pass, fail, clamp, test type, exhaust and custom
    Analog outputs: single channel, 0-5 VDC pressure control
  2. Pneumatic connections:
    Test Ports
    Air supply: ¼” Swagelok
    Vacuum: 3/8” to 1” NW
    (Application dependent)
  3. RS232 Serial Interface
  4. Power Supply:
    115VAC-60Hz
    220VAC-50Hz (optional)

Print Model ME2 - PDF (563K)


Top of Page