Please Note: You are viewing the unstyled version of ATC, Inc. Either your browser does not support CSS (Cascading Style Sheets) or it is disabled. As a result, much of this website will not look the way it was intended, although all of its contents will be accessible to you. For more information, visit our Browser Support page.


Skip to Primary Site Navigation, Secondary Site Navigation, Content, Company Address


Home > Flow Calibration / Measurement > GAS-CAL© > System Specifications

GAS-CAL© System Specifications

GAS-CAL©

Gas Flow Measurement

Maximum Flow Capacity of System: 50,000 LPM

Flow Standards Configuration:

  • Up to 6 calibrated flow measurement standards
  • Low flow standards are accelerated laminar flow (ALF)(See Flow Sensor specification sheets.) Critical venturi nozzles for high range up to 50,000 LPM
  • Selectable flow units of mass and volumetric measure: cc/min, LPM, L/hr, GPM, cubic meters/hours, g/sec, kg/min, lb/min, kg/hr, and lb/hr

Overall Uncertainty: ±0.25% of reading Calibrated Range (Critical Venturi) or ±0.5% of reading, Calibrated Range (IGFS Sensors).

Over Flow Range Condition: Should gas flow through the system exceed the maximum flow rate, the operator will be prompted to take appropriate action.

Maximum Working Pressure: 500 PSIG or pressure sensor range whichever is the lesser.

Gas Media:

  • Multiple non-corrosive gasses are supported, typically air, nitrogen, CO2 natural gas, hydrogen.
  • Other Gases Available, consult ATC

Pressure Measurement: for critical venturi nozzles.

  • Digiquartz type pressure standard
  • Located upstream to nozzle
  • Uncertainty: ±0.01% FS

Pressure Measurement: for IGFS.

  • Silicon piezoresistive type pressure sensor
  • Uncertainty: ±0.1% FS
  • All pressure measurements are temperature compensated

Temperature Measurement:

  • 100 Ohm platinum element RTD probe
  • Uncertainty ±-0.3°C

Environment:

  • Temperature: 0 to 50°C, operating
  • -25 to 85°C, storage

Relative Humidity: 95% non-condensing.

Critical Venturi Nozzle Design: Stainless steel toroidal throat nozzles per ASME / ANSI MFC-7M, polished at throat and critical flow area, with inlet flow straightener and outlet pressure recovery diffuser.

System Calibration: Each unit is supplied complete with calibration certificates traceable to the National Institute of Standards and Technology (NIST) and uncertainty analysis.

* All measurement uncertainties are per ANSI/NCSL Z540-2-1997 and ISO/IEC 17025:2005